Customization: | Available |
---|---|
Condensation Forms: | Air-Cooled |
Refrigerant: | R-22 R-404A R-134A |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
![]() |
![]() |
The refrigeration equipment on vessel needs to be carefully designed to adapt to the complex use environment. We design it individually for each customer and bring unique equipment as follow:
* Anti-corrosion design * Humanization design Safe and stable * Power saving system * Special design on vessel All these improvements are designed to allow customers to get the best user experience. Below is a detailed introduction to a program about one of our customers on vessel.
|
![]() |
![]() |
* All materials are treated by sand blasted before painting.
* system is with ocean vessel painting, 3 layers
|
* Condenser shell with SS316, operate well in ocean.
* Inner pipe with cupronickel, apply better to ocean water.
* Edge cap with Zinc block as anode.
|
![]() |
![]() |
Bitze screw compressor in application * Bitze brand compressor, No.1 quality assure. * Screw compressor, less accessories, higher reliability quality than reciprocating compressor.
* No unbalanced inertial force,
smooth and stable, especially better used on fishing boat.
* Capacity control, from 15%~100%
|
Danfos VFD in application * Soft start, Reduce the impact on the grid. * Adjust the frequency from 70Hz to 15Hz.
Power saving.
|
![]() |
Customize the size and style of the system according to each actual usage scenario.
* Most accessories we design together, leave outlet and inlet pipe, easy to install on site.* Sight glass, gauge and dry filter we design the left side of unit. Easy to check and maintain. |
* Design the modular system
dimension as 3.0x1.8x1.587m according to engine room. * Refrigeration system locates beside the engine, there is a inspection path between them |
![]() |
![]() |
![]() |
Suction accumulator with heat exchanger * Heat the liquid refrigerant in tank, supplement to complete system.
* Control liquid volume in tank, protect compress
|
Independent condenser and receiver * Reasonable use space of engine room.
* Make sure condenser position is higher than receiver, condensed gas go back to receiver easily.
|
![]() |
![]() |
Plenty of valves in system * If refrigerant leak, or replace accessories, we can shut down vales and do next easily. * Inlet and outlet of filter. * Inlet and outlet of compressor. * Inlet and outlet of suction accumulator. * Inlet and outlet of receiver. * Inlet and outlet of oil separator. |
Merchanical control advantages * Safe and stable for control system, especially on ocean when fishing, not be broken easily. * Easy to replace and maintenance accessories. * Independent control each compressor, can control compressor conveniently according to fishing situation. |
![]() |
![]() |
![]() |