Customization: | Available |
---|---|
Condensation Forms: | Air-Cooled |
Refrigerant: | R-22 R-404A R-134A |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
The refrigeration equipment on vessel needs to be carefully designed to adapt to the complex use environment. We design it individually for each customer and bring unique equipment as follow:
* Anti-corrosion design * Humanization design Safe and stable * Power saving system * Special design on vessel All these improvements are designed to allow customers to get the best user experience. Below is a detailed introduction to a program about one of our customers on vessel.
|
* All materials are treated by sand blasted before painting.
* system is with ocean vessel painting, 3 layers
|
* Condenser shell with SS316, operate well in ocean.
* Inner pipe with cupronickel, apply better to ocean water.
* Edge cap with Zinc block as anode.
|
Bitze screw compressor in application * Bitze brand compressor, No.1 quality assure. * Screw compressor, less accessories, higher reliability quality than reciprocating compressor.
* No unbalanced inertial force,
smooth and stable, especially better used on fishing boat.
* Capacity control, from 15%~100%
|
Danfos VFD in application * Soft start, Reduce the impact on the grid. * Adjust the frequency from 70Hz to 15Hz.
Power saving.
|
Customize the size and style of the system according to each actual usage scenario.
* Most accessories we design together, leave outlet and inlet pipe, easy to install on site.* Sight glass, gauge and dry filter we design the left side of unit. Easy to check and maintain. |
|
* Design the modular system
dimension as 3.0x1.8x1.587m according to engine room. * Refrigeration system locates beside the engine, there is a inspection path between them |
Suction accumulator with heat exchanger * Heat the liquid refrigerant in tank, supplement to complete system.
* Control liquid volume in tank, protect compress
|
Independent condenser and receiver * Reasonable use space of engine room.
* Make sure condenser position is higher than receiver, condensed gas go back to receiver easily.
|
Plenty of valves in system * If refrigerant leak, or replace accessories, we can shut down vales and do next easily. * Inlet and outlet of filter. * Inlet and outlet of compressor. * Inlet and outlet of suction accumulator. * Inlet and outlet of receiver. * Inlet and outlet of oil separator. |
Merchanical control advantages * Safe and stable for control system, especially on ocean when fishing, not be broken easily. * Easy to replace and maintenance accessories. * Independent control each compressor, can control compressor conveniently according to fishing situation. |