Customization: | Available |
---|---|
Temperature: | -40 ~ 20 Degree |
Refrigerant: | R-22 R-404A R-134A |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
2HP 3HP 5HP Monoblock Condensing Unit Air Cooled Freezer Evaporator for Cold Room
The air cooler is the second largest component in the refrigeration system. It is used for heat exchange inside the cold storage. The conversion method is to multiply the number of compressors by 8 to get the model of the DD type air cooler. The principle is based on the large principle, and then select the corresponding one according to the actual storage temperature. Corresponding model
Evaporator classification:
Evaporator | Single side wind | high temperature | DL | High temperature type, 4.5mm pitch, suitable for cold storage above 0 degrees |
medium temperature | DD | Medium temperature type, 6mm pitch, suitable for cold storage above -18 degrees | ||
low temperature | DJ | Low temperature type, 9 mm pitch, suitable for -25 degrees cold storage | ||
quick freezing | DCJ | Quick-frozen type, 12 mm pitch, suitable for -35 degrees cold storage | ||
Double air outlet,For food processing, cold storage such as mushroom growth storage | high temperature | SDL | High temperature type, 4.5mm pitch, suitable for food processing workshops above 5 degrees | |
medium temperature | SDD | Medium temperature type, 6mm sheet distance, suitable for low temperature storage, cold storage with small air volume requirements |
Evaporator parameters:
Model |
HP |
Capacity (kW) |
areas (m2) |
Fan(380V) | Electrical heater 220v(Kw) |
Into tube (mm) |
Back tube (mm) |
GW (Kg) |
Package Size L*W*H (mm) |
|||
Power (W) |
Air-volume (m3/h) |
Diameter (mm) |
Coil | Drip pan | ||||||||
DD-1.4/7 | 1 | 1.4 | 7 | 90 | 1*1710 | 300 | 0.5 | 0.5 | 12 | 16 | 26 | 820*470*600 |
DD-2.4/12 | 1.5 | 2.4 | 12 | 2*90 | 2*1700 | 300 | 0.7 | 0.7 | 12 | 16 | 33 | 820*520*600 |
DD-3.0/15 | 2 | 3.0 | 15 | 2*90 | 2*1700 | 300 | 0.8 | 0.8 | 12 | 19 | 48 | 1220*470*600 |
DD-4.0/22 | 3 | 4.0 | 22 | 2*120 | 2*2200 | 300 | 1.6 | 0.8 | 12 | 19 | 53 | 1220*520*600 |
DD-6.0/30 | 4 | 6.0 | 30 | 2*200 | 2*3500 | 400 | 2.0 | 1.0 | 16 | 25 | 65 | 1520*520*600 |
DD-8.0/40 | 5 | 8.0 | 40 | 2*200 | 2*3500 | 400 | 2.0 | 1.0 | 16 | 25 | 85 | 1520*520*700 |
DD-12/60 | 7.5 | 12.0 | 60 | 2*250 | 2*4950 | 450 | 6.0 | 1.2 | 19 | 30 | 140 | 1820*520*800 |
DD-16/80 | 10 | 16.0 | 80 | 2*250 | 2*4950 | 450 | 6.0 | 1.2 | 19 | 30 | 157 | 1920*600*800 |
DD-20/100 | 12.5 | 20.0 | 100 | 3*250 | 3*4950 | 450 | 8.0 | 1.6 | 19 | 38 | 200 | 2300*600*800 |
DD-24/120 | 15 | 24.0 | 120 | 3*250 | 3*4950 | 450 | 10.0 | 2.0 | 19 | 38 | 220 | 2700*600*800 |
DD-28.0/140 | 17.5 | 28.0 | 140 | 4*250 | 4*4950 | 450 | 11.0 | 2.2 | 25 | 45 | 250 | 3140*600*800 |
DD-32/160 | 20 | 32.0 | 160 | 4*250 | 4*4950 | 450 | 12.5 | 2.5 | 25 | 45 | 290 | 3540*600*800 |
DD-37.4/200 | 25 | 37.4 | 200 | 2*1500 | 2*10000 | 600 | 13.6 | 1.7 | 25 | 50 | 370 | 2340*1120*1200 |
DD-46.8/250 | 30 | 46.8 | 250 | 3*1500 | 3*10000 | 600 | 16.0 | 2.0 | 25 | 50 | 450 | 2820*1120*1200 |
DD-56.2/310 | 38 | 56.2 | 310 | 3*1500 | 3*10000 | 600 | 19.2 | 2.4 | 25 | 50 | 470 | 3300*1120*1200 |
Model |
HP |
Capacity (kW) |
areas (m2) |
Fan(380V) | Electrical heater (220V) (Kw) |
Into tube (mm) |
Back tube (mm) |
GW (Kg) |
Package Size L*W*H (mm) |
|||
Power (W) |
Air-flow (m3/h) |
Diameter (mm) |
||||||||||
DJ-0.8/5 | 1 | 0.8 | 5 | 90 | 1*1700 | 300 | 0.7 | 0.7 | 12 | 16 | 26 | 820*470*600 |
DJ-1.3/8 | 1.5 | 1.3 | 8 | 2*90 | 2*1700 | 300 | 0.7 | 0.7 | 12 | 16 | 33 | 820*520*600 |
DJ-1.8/10 | 2 | 1.8 | 10 | 2*90 | 2*1700 | 300 | 0.8 | 0.8 | 12 | 19 | 48 | 1220*470*600 |
DJ-2.1/15 | 3 | 2.1 | 15 | 2*120 | 2*2290 | 350 | 1.6 | 0.8 | 12 | 19 | 53 | 1220*520*600 |
DJ-4.0/20 | 4 | 4.0 | 20 | 2*200 | 2*3500 | 400 | 2.0 | 1.0 | 16 | 25 | 65 | 1520*520*600 |
DJ-6.0/30 | 5 | 6.0 | 30 | 2*200 | 2*3500 | 400 | 2.0 | 1.0 | 16 | 25 | 85 | 1520*520*700 |
DJ-8.0/40 | 7.5 | 8.0 | 40 | 2*250 | 2*4950 | 450 | 6.0 | 1.2 | 19 | 30 | 140 | 1820*520*800 |
DJ-11/55 | 10 | 11.0 | 55 | 2*250 | 2*4950 | 450 | 6.0 | 1.2 | 19 | 30 | 157 | 920*600*800 |
DJ-13/70 | 12.5 | 13.0 | 70 | 3*250 | 3*4950 | 450 | 8.0 | 1.6 | 19 | 38 | 200 | 2300*600*800 |
DJ-16/85 | 15 | 16.0 | 85 | 3*250 | 3*4950 | 450 | 10.0 | 2.0 | 19 | 38 | 220 | 2700*600*800 |
DJ-18.8/100 | 17.5 | 18.8 | 100 | 4*250 | 4*4950 | 450 | 11.0 | 2.2 | 25 | 45 | 250 | 3140*600*800 |
DJ-21.6/115 | 20 | 21.6 | 115 | 4*250 | 4*4950 | 450 | 12.5 | 2.5 | 25 | 45 | 290 | 3540*600*800 |
DJ-23.9/140 | 25 | 23.9 | 140 | 2*1500 | 2*10000 | 600 | 13.6 | 1.7 | 25 | 50 | 370 | 2340*1120*1200 |
DJ-29.0/170 | 30 | 29.0 | 170 | 3*1500 | 3*10000 | 600 | 16.0 | 2.0 | 25 | 50 | 450 | 2820*1120*1200 |
DJ-35.9/210 | 38 | 35.9 | 210 | 3*1500 | 3*10000 | 600 | 19.2 | 2.4 | 25 | 50 | 470 | 3300*1120*1200 |
Model |
Capacity (kW) |
areas (m2) |
Fan(380V) | Electrical heater (220V) (Kw) |
Into tube (mm) |
Back tube (mm) |
GW (Kg) |
Package Size L*W*H (mm) |
|||
Power (W) |
Air-volume (m3/h) |
Diameter (mm) |
|||||||||
DL-2.1/10 | 2.1 | 10 | 90 | 1*1700 | 300 | 0.5 | 0.5 | 12 | 16 | 26 | 820*470*600 |
DL-3.1/15 | 3.1 | 15 | 2*90 | 2*1700 | 300 | 0.7 | 0.7 | 12 | 16 | 33 | 820*520*600 |
DL-4.1/20 | 4.1 | 20 | 2*90 | 2*1700 | 300 | 0.8 | 0.8 | 12 | 19 | 48 | 1220*470*600 |
DL-5.2/25 | 5.2 | 25 | 2*120 | 2*2200 | 350 | 0.8 | 0.8 | 12 | 19 | 53 | 1220*520*600 |
DL-8.3/40 | 8.3 | 40 | 2*200 | 2*3500 | 400 | 2.0 | 1.0 | 16 | 25 | 65 | 1520*520*600 |
DL-11.5/55 | 11.5 | 55 | 2*200 | 2*3500 | 400 | 2.0 | 1.0 | 16 | 25 | 85 | 1520*520*700 |
DL-16.7/80 | 16.7 | 80 | 2*250 | 2*4800 | 450 | 2.4 | 1.2 | 19 | 30 | 140 | 1820*520*800 |
DL-22/105 | 22.0 | 105 | 2*250 | 2*4950 | 450 | 2.4 | 1.2 | 19 | 30 | 157 | 1920*600*800 |
DL-27.3/130 | 27.3 | 130 | 3*250 | 3*9450 | 450 | 3.2 | 1.6 | 19 | 38 | 200 | 2300*600*800 |
DL-33.6/160 | 33.6 | 160 | 3*250 | 3*4950 | 450 | 4.0 | 2.0 | 19 | 38 | 220 | 2700*600*800 |
DL-38.7/185 | 38.7 | 185 | 4*250 | 4*4950 | 450 | 4.4 | 2.2 | 25 | 45 | 250 | 3140*600*800 |
DL-44.0/210 | 44.0 | 210 | 4*250 | 4*4950 | 450 | 5.0 | 2.5 | 25 | 45 | 290 | 3540*600*800 |
DL-52.9/260 | 52.9 | 260 | 2*1500 | 2*10000 | 600 | 8.5 | 1.7 | 25 | 50 | 370 | 2340*1120*1200 |
DL-67.2/330 | 67.2 | 330 | 3*1500 | 3*10000 | 600 | 10.0 | 2.0 | 25 | 50 | 450 | 2820*1120*1200 |
DL-83.4/410 | 83.4 | 410 | 3*1500 | 3*10000 | 600 | 12.0 | 2.4 | 25 | 50 | 470 | 3300*1120*1200 |
Condensing units are the the most important component of whole cold room. Condensing unit typically is a high assembly of a refrigeration system which includes an assembly of compressor, condenser, fan motor, controls and a mounting plate. ONLYKEM designs and fabricates a versatile line of air cooled, water cooled and remote condensing units ranging from small cold room monoblock refrigeration unit to very large industrial rack refrigeration system.
Our high quality, innovative condensing unit products include outdoor condensing unit, Indoor condensing unit, vertical air cooled condensing unit, rack refrigeration system and monoblock refrigeration unit, which are engineered for energy efficiency and serviceability and are offered with a full selection of standard features and options to meet any commercial refrigeration applications.
Condensing Unit •Compressor Optional: 1-Hermetic Scroll 2-Semi-hermetic or Screw •Condenser:Air cooled or Water cooled •Frame:can be stell shell with spray painting or open type on stell frame •Refrigerant:R404a/R410a •Capacity:Singe compressor 2HP-50HP |
|
Smart Packaged Unit •Compressor HP: 2-15hp •Working Temp.:+5~-30ºC •Compressor Type: Scroll / Rotary •Independent developed smart CDU(Condensing Unit) controller •Advanced fuzzy controlled EXV module •Intelligent hot-gas defrost on demand •Condenser fan-speed controls •Self-diagnosis function Intelligent alarm system |
Advantages for our condensing unit |
|
1.The accessories for the unit include liquid receiver, pressure gage, pressure controller, sight glass, filter junction box,etc. 2.The copper tube of air cooled Condensing units get through the 2.6Mpa pressure test, meet the request of normal work. 3.Every part of units is best in corrosion protection. 4.Air cooled condensing unit refrigerating capacity ranks from 0.2KW to 29KW.evaporating temperature:-45°C-+15°C, run steady under the ambient temperature +43°C. 5.Proper structure, accurate and reliable operating system for the air cooled condensing unit. 6.Use the high efficiency and large air volume axial fan, with low noise and energy saving. |
|
How to recognize original Bitzer compressor? |
|
TO MAKE SURE THAT YOU HAVE AN ORIGINAL BITZER COMPRESSOR
|